Chapter 8 Troubleshooting

Scanned images turn out elongated.

Are the rollers dirty?

 

 

 

Clean the rollers.

 

 

 

 

 

 

 

For more information on cleaning, refer to "6.2 Cleaning the ADF (with Cleaning

 

Yes

 

Sheet)" (page 121) or "6.3 Cleaning the ADF (with cloth)" (page 123).

 

 

 

 

 

No

TOP

Contents

Index

Introduction

Scanner

Overview

Does the condition of the documents fulfill the requirements described in "Precautions" in "Paper Quality" (page 40)?

Yes

Are any of the consumables (*1) worn out?

No

Have you adjusted [Offset/Vertical Magnification Adjustment]?

Yes

Use a document that satisfies the required conditions.

For more details, refer to "2.2 Documents for Scanning" (page 40).

No

 

 

 

Check the consumable counters. Replace the consumables if necessary.

 

 

 

 

 

 

For information on how to replace consumables, refer to "Chapter 7 Replacing

Yes

Consumables" (page 130).

 

 

 

 

 

 

 

 

 

 

 

In [Hardware Setting] of the Software Operation Panel, adjust the scan scale in the

 

 

 

 

 

 

feeding direction.

 

No

 

For more details, refer to "Adjusting the Starting Position for Scanning [Offset/

 

 

 

Vertical Magnification Adjustment]" (page 186).

 

 

 

 

 

 

 

 

 

 

 

If the above countermeasures do not solve the problem, check the items in "8.4

 

 

 

Before You Contact the Scanner Service Provider" (page 166) first, then contact

 

 

 

your FUJITSU scanner dealer or an authorized FUJITSU scanner service provider.

 

 

 

 

How to Load Documents

Configuring the Scan Settings

How to Use the Operator Panel

Various Ways to Scan

Daily Care

*1: "Consumables" refers to the pick roller, separator roller and brake roller.

Replacing Consumables

Troubleshooting

Operational Settings

Appendix Glossary

163