Chapter 9 Operational Settings
Item | Description | Setting/Value | Factory Default | SCSI or USB | SCSI or USB |
|
|
|
| Connector 1 | Connector 2 |
|
|
|
|
|
|
|
|
|
| 3: Configurable | |
|
|
|
| ||
|
|
|
|
|
|
Retain current | Specify whether or not to keep the | Remember / Do not remember | Do not remember | 3 | 3 |
paper thickness | operator panel’s paper separation |
|
|
|
|
| force setting upon turning the power |
|
|
|
|
| off. |
|
|
|
|
|
|
|
|
|
|
Cleaning Cycle | Specify the cycle for cleaning the | 1,000 to 255,000 sheets | 10,000 sheets | 3 | 3 |
| scanner. | (in increments of 1,000) |
|
|
|
| Also specify whether or not to show | [Show cleaning instructions.] check box | Not selected |
|
|
| a message for cleaning from the |
|
|
|
|
| scanner driver. |
|
|
|
|
|
|
|
|
|
|
Life Counter Alarm | Specify the replacement cycles for | Each consumable | 600,000 sheets | 3 | 3 |
Setting | the consumables. | 10,000 to 2,550,000 sheets |
|
|
|
|
| (in increments of 10,000) |
|
|
|
|
|
|
|
|
|
Set the interval for | If the bottom of the scanned image | Short (default) - Long | Short (default) | 3 | 3 |
feeding sheets | is partially missing due to a large | (1 to 4 levels) |
|
|
|
| skew when scanning in Automatic |
|
|
|
|
| Page Size Detection, specify a |
|
|
|
|
| longer interval to feed the |
|
|
|
|
| documents. |
|
|
|
|
| Specifying a longer interval leaves |
|
|
|
|
| more time between each document |
|
|
|
|
| to be scanned. |
|
|
|
|
|
|
|
|
|
|
Pick Speed | When multifeeds or paper jams | Normal / Slower | Normal | 3 | 3 |
| occur frequently, the symptom may |
|
|
|
|
| be improved by slowing down the |
|
|
|
|
| speed (pick speed) in which the |
|
|
|
|
| documents are fed. |
|
|
|
|
| It can also be configured from the |
|
|
|
|
| operator panel. |
|
|
|
|
|
|
|
|
|
|