Chapter 9 Operational Settings
The following may sometimes appear while using the scanner:
Consumable replacement message:
Cleaning message:
According to the instruction displayed, clean the scanner or replace the consumables.
When you click the [Ignore] button, the cleaning instruction disappears and the scanning continues. You may be able to continue scanning for a while, however, it is recommended that you replace the consumable(s) as soon as possible.
To stop the scan and replace the consumable(s) right away, click the [Cancel] button.
For information on how to replace the consumables, refer to the following sections:
zPick Roller "7.2 Replacing the Pick Roller" (page 132)
zSeparator Roller "7.3 Replacing the Separator Roller" (page 134)
zBrake Roller "7.4 Replacing the Brake Roller" (page 137)
For information on how to clean the scanner, refer to "Chapter 6 Daily Care" (page 118).
You can specify the cleaning cycle for the scanner.
The background color of the counter changes to yellow when the page count after cleaning reaches 100% of the value specified here.
You can also display the message for cleaning (page 184).
1 Start up the Software Operation Panel.
Refer to "9.1 Starting Up the Software Operation Panel" (page 170).
2 From the listing on the left, select [Device Setting 2] J [Cleaning Cycle].
3 Specify a value to determine when to clean the scanner.
The specifiable value is from 1,000 to 255,000 in increments of 1,000. Also specify whether or not to display the cleaning message.
184