Chapter 9 Operational Settings

Item

Description

Setting/Value

Factory Default

SCSI or USB

SCSI or USB

 

 

 

 

Connector 1

Connector 2

 

 

 

 

 

 

 

 

 

 

3: Configurable

 

 

 

 

-: Not configurable

 

 

 

 

 

 

Soft Pick Setting

When you experience pick errors

Enable / Disable

Enable

3

3

 

from the separator roller slipping on

 

 

 

 

 

the paper, or paper jams from

 

 

 

 

 

scanning thin papers of small

 

 

 

 

 

widths, the symptom may be

 

 

 

 

 

improved by bringing down the pick

 

 

 

 

 

roller unit and keeping the unit at the

 

 

 

 

 

lower position (disabling the Soft

 

 

 

 

 

Pick Setting).

 

 

 

 

 

It can also be configured from the

 

 

 

 

 

operator panel.

 

 

 

 

 

 

 

 

 

 

AutoCrop

Specify whether or not to optimize

Normal / Optimize

Normal

3

-

Boundary

(round up/down) the fractional part

 

 

 

 

 

of the scanned image data.

 

 

 

 

 

 

 

 

 

 

Auto color

Specify the slice level for automatic

1 to 255 levels

5

3

-

Detection

color/monochrome detection.

 

 

 

 

 

 

 

 

 

 

Alarm setting

Specify whether or not to sound an

Disable alarm / Low volume alarm /

Disable alarm

3

3

 

alarm when an error such as

High volume alarm

 

 

 

 

multifeed or paper jam occurs.

 

 

 

 

 

It can also be configured from the

 

 

 

 

 

operator panel.

 

 

 

 

 

 

 

 

 

 

Jam Detection

Specify whether or not to judge the

Enable / Disable

Enable

3

3

outside of

symptom as paper jam when a

 

 

 

 

scannable area

document is skewed and passes

 

 

 

 

when transporting

outside the supported scanning

 

 

 

 

paper

area.

 

 

 

 

 

 

 

 

 

 