Chapter 9 Operational Settings
Item | Description | Setting/Value | Factory Default | SCSI or USB | SCSI or USB |
|
|
|
| Connector 1 | Connector 2 |
|
|
|
|
|
|
|
|
|
| 3: Configurable | |
|
|
|
| ||
|
|
|
|
|
|
Maintenance and | Specify the cycle for scanner | Disable / Enable | Disable | 3 | 3 |
Inspection Cycle | maintenance and inspection to be | Maintenance/Inspection cycle: 1 to 12 |
|
|
|
| performed by a service engineer. | months |
|
|
|
| When the specified time period |
|
|
|
|
| elapses since the last periodical |
|
|
|
|
| maintenance and inspection, a |
|
|
|
|
| message for periodical maintenance |
|
|
|
|
| appears. |
|
|
|
|
|
|
|
|
|
|
Multi dropout | Specify a color to be dropped out | Use driver settings / Custom | Use driver | - | 3 |
colors | from the scanned image (black & |
| settings |
|
|
| white/grayscale mode only). You |
|
|
|
|
| can select any color(s) to drop out in |
|
|
|
|
| [Multi dropout colors]. |
|
|
|
|
| Note that priority is given to the |
|
|
|
|
| scanner driver setting if any dropout |
|
|
|
|
| color has been specified in the |
|
|
|
|
| scanner driver’s setup dialog box. |
|
|
|
|
|
|
|
|
|
|
Overscan Control | Outputs the image in the optimum | Normal / Optimize | Normal | 3 | - |
| position when the image is partially | Black frame thickness: Thin (Default) to |
|
|
|
| missing due to a large skew. | Thick (level 1 to 3) |
|
|
|
|
|
|
|
|
|
181