Chapter 4 How to Use the Operator Panel
Item | Description | Setting/Value | Factory Default |
|
|
|
|
|
|
| |
|
|
|
|
7: MF Quick | Enables you to switch whether or not to detect multifeed by a push | 1: Disable | 1: Disable |
Change | of a button. Priority is given to the driver setting when [1: Disable] | 2: Enable(Detect) |
|
| is selected. | 3: Enable(Ignore) |
|
| When [2: Enable(Detect)] or [3: Enable(Ignore)] is selected, it |
|
|
| switches between detecting/not detecting multifeed every time the |
|
|
| [Eject] button is pressed. It can be switched during scanning. |
|
|
| For [2: Enable(Detect], it detects multifeed by default and |
|
|
| multifeed detection is performed according to the driver setting. |
|
|
| For [3: Enable(Ignore)], it does not detect multifeed by default and |
|
|
| this setting is given priority over the driver setting. |
|
|
|
|
|
|
8: Alarm Volume | Specify whether or not to ring an alarm when an error such as | 1: OFF | 1: OFF |
| multifeed or paper jam occur. | 2: Low |
|
| It can also be configured from the Software Operation Panel. | 3: High |
|
|
|
|
|
9: Stacker | Adjust the stacker position. | 1: Movable | (*1) |
Positioning | You can set the stacker at certain heights. | 2: Fixed |
|
|
|
|
|
10: Hopper Level | Change the hopper level during standby. Selecting [1: Manual | 1: Manual (Continuous) | (*2) |
| (Continuous)] switches the scanner to Manual Feed mode | 2: Upper |
|
| (Continuous Feed mode). The hopper level cannot be changed in | 3: Middle |
|
| Manual Feed mode (Single Feed mode). | 4: Lower |
|
| Remove all documents from the hopper when you configure this |
|
|
| item. |
|
|
| The hopper is set to [4: Lower] when you clear manual feeding |
|
|
| (continuous). |
|
|
|
|
|
|
11: Paper | When you experience frequent multifeeds, pick errors or paper | Low High | |
Separation | jams, take measures by adjusting the force to separate the | |
|
Force | papers. | |
|
| Keep the default setting for normal use. | |
|
| For more details, refer to "1.9 Adjusting the Paper Separation | |
|
| |
| |
|
|
|
|
12: Alarm Sound | Specify the duration to ring the alarm in when errors such as | 0.5, 1, 1.5, 2.0, 2.5 (seconds) | 2.0 |
Time | multifeed and paper jam occur. |
|
|
|
|
|
|
76