Chapter 9 Operational Settings

Range

Description

 

 

End

Displays the end point of the detection by

(Left/Middle/Right)

the length from the leading edge of the

 

document.

 

Configurable area: 0 to 510 mm (in

 

increments of 2 mm), Start < End

 

 

zWhen both [Start] and [End] are set to "0", multifeed detection is performed for the whole area regardless of whether it is enabled or disabled.

zTo disable multifeed detection for the whole document, select [Disable] and set the start position to "0" and the end position to be equal to or longer than the document length.

zIf the start position is set larger than the document length: with [Disable], the whole range covering the entire document length will be checked; with [Enable], the multifeed detection will be disabled.

zTo detect multifeeds, the detection range must be at least 8 mm in length.

Configure the settings so that the value of the end position minus the start position is 6 mm or more.

zYou can also set the start and the end positions by one of the following ways:

-Create a square or rectangle to indicate the detection range by dragging your mouse pointer on the displayed image in the dialog box.

-Drag the handle for the detection range to change the start and end positions using the mouse pointer on the displayed image in the dialog box.

Example 1:

zSpecified position: Left

Selected range = Disable, Start = 50 mm, End = 200 mm

zSpecified position: Middle

Selected range = Enable, Start = 50 mm, End = 200 mm

zSpecified position: Right

Selected range = Disable, Start = 50 mm, End = 200 mm

35 35 35

direction

50

Feeding

200

 

Unit: mm

60 60

Multifeed is detected only for the areas in light blue.