Chapter 9 Operational Settings

Example 2:

zSpecified position: Left

Selected range = Disable, Start = 0 mm, End = 300 mm or more

zSpecified position: Middle

Selected range = Enable, Start = 0 mm, End = 0 mm

zSpecified position: Right

Selected range = Disable, Start = 0 mm, End = 0 mm

35 35 35

directionFeeding 300

Unit: mm

60 60

Multifeeds are detected only for the areas in light blue.

When detecting the overlapping of documents, the multifeed detection rate may drop if the documents are glued tightly or attached together by static electricity.

Example 3: (Bad example)

zSpecified position: Left

Selected range = Disable, Start = 310 mm, End = 400 mm

zSpecified position: Middle

Selected range = Enable, Start = 320 mm, End = 450 mm

zSpecified position: Right

Selected range = Enable, Start = 100 mm, End = 102 mm

35 35 35

direction

100

Feeding

2

 

 

300

Unit: mm

60 60

Since the detection range (length) is less than 8 mm, multifeeds cannot be detected correctly.