A - 10
(1) Servo amplifiers and servo motors used
Use the servo amplifiers and servo motors whic h comply with the standard model.
Servo amplifier :MR-J3-10T to MR-J3-22KT
MR-J3-10T1 to MR-J3-40T1
MR-J3-60T4 to MR-J3-22KT4
Servo motor :HF-MP
HF-KP
HF-SP
(Note)
HF-SP
4 (Note)
HC-RP
HC-UP
HC-LP
HA-LP
(Note)
HA-LP
4 (Note)
Note. For the latest information of compliance, contact Mitsubishi.
(2) Installation
Install a fan of 100CFM (2.8m3/min) air flow 4[in] (10.16[cm]) above th e servo amplifier or provide cooling
of at least equivalent capability to ensure that the ambient temperature conforms to the environment
conditions (55 or less).
(3) Short circuit rating (SCCR: Short Circuit Current Rating)
Suitable For Use In A Circuit Capable Of Deli vering Not More Than 100 kA rms Symmetrical Am peres, 500
Volts Maximum.
(4) Capacitor discharge time
The capacitor discharge time is as listed belo w. To ensure safety, do not touch the charging s ection for 15
minutes after power-off.
Servo amplifier Discharge time
[min]
MR-J3-10T 20T 1
MR-J3-40T 60T(4) 10T1 20T1 2
MR-J3-70T 3
MR-J3-40T1 4
MR-J3-100T(4) 5
MR-J3-200T(4) 350T 9
MR-J3-350T4 500T(4) 700T(4) 10
MR-J3-11KT(4) 4
MR-J3-15KT(4) 6
MR-J3-22KT(4) 8