7 - 5
7. MR Configurator
7.4 Parameters
Click "Parameters" on the menu bar and click "Parameter list" on the menu.
When the above choices are made, the following window appears.
g) h) i) j) k) l)
c) a) f)
b) d) e)
(1) Parameter value write ( a) )
Click the parameter whose setting was changed and press the "Write" button to write the ne w parameter
setting to the servo amplifier.
(2) Parameter value verify ( b) )
Click the "Verify" button to verify all param eter values being displayed and the parameter values of the
servo amplifier.
(3) Parameter value batch-read ( c) )
Click the "Read All" button to read and disp lay all parameter values from the servo amplifi er.