5 - 49
5. OPERATION
(2) Timing chart Forward
rotation
0r/min
Reverse
rotation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Automatic/manual selection
(RYn6)
Rough match (RXn2)
Servo motor speed
Proximity dog (DOG)
Forward rotation start (RYn1)
Home position return speed
Creep speed
Home position shift distance
6ms or more
3ms or less
Reverse rotation start (RYn2)
Selected point table No. 0
4ms or more (Note)
ON
OFF
Z-phase
Proximity dog
Home position address
parameter No.PC07
Movement completion (RXnC)
Home position return
completion (RXn3/ZP)