5 - 30
5. OPERATION
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.PA05 to set the multiplicatio n ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No.PA05 setting Multiplication ratio of servo motor rotation to
manual pulse generator rotation Moving distance
0 1 time 1[ m]
1 10 times 10[m]
2 100 times 100[m]
(b) Using the input signals for setting (devices)
Set the pulse generator multiplication 1 (TP0) and the puls e generator multiplication 2 (TP1) to the CN6
connector pins in the parameters of Nos. PD06 to PD08.
(Note)
Pulse generator multiplication 2
(TP1)
(Note)
Pulse generator multiplication 1
(TP0)
Multiplication ratio of servo motor rotation
to manual pulse generator rotation Moving distance
0 0 Parameter No.PA05 setting valid
0 1 1 time 1[ m]
1 0 10 times 10[ m]
1 1 100 times 100[m]
Note. 0: OFF
1: ON
(4) Operation
Turn the manual pulse generator to rotate the servo m otor. For the rotation direction of servo motor, refer to
(2) in this section.