14 - 43
14. OPTIONS AND AUXILIARY EQUIPMENT
14.4 Power regeneration converter
When using the power regeneration converter, set " 01" in parameter No.PA02.
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are appl ied to the
servo amplifiers of the 5k to 22kW.
Power regeneration
converter
Nominal
regenerative power
(kW)
Servo amplifier
FR-RC-15K 15
MR-J3-500T
MR-J3-700T
FR-RC-30K 30
MR-J3-11KT
MR-J3-15KT
FR-RC-55K 55 MR-J3-22KT
FR-RC-H15K 15 MR-J3-500T4
MR-J3-700T4
FR-RC-H30K 30
MR-J3-11KT4
MR-J3-15KT4
FR-RC-H55K 55 MR-J3-22KT4
0 50 75 100 150
500
300
200
100
50
30
20
Continuous energization time [sec
]
Nominal regenerative power (%)