16 - 35
16. INDEXER POSITIONING OPERATION
16.5.5 Point table setting
Set necessary items to the point table before starting operatio n. The following table indicates the items that
must be set.
Name Description
Position data Not used in indexer positioning operation.
Do not change this value by any means.
Servo motor speed Set the command speed of the servo motor for execution of positioning.
Acceleration time constant Set the acceleration time constant.
Deceleration time constant Set the deceleration time constant.
Dwell Not used in indexer positioning operation.
Do not change this value by any means.
Auxiliary function Not used in indexer positioning operation.
Do not change this value by any means.
16.5.6 Actual operation
Start actual operation after confirmation of norm al operation by test operation and completion of the
corresponding parameter settings. Perform a hom e position return as necessary.