3 - 31
3. CC-LINK COMMUNICATION FUNCTIONS
3.5.5 Respond codes (RWrn+2)
If any of the monitor codes, instruction codes, position command data/point table Nos., speed command
data/point table Nos. set to the remote register is outside the setting range, the correspondi ng error code is set
to respond code (RWwn+2). "0000" is set if th ey are normal.
Error related to Monitor code 1/Monitor code 2
Error related to Instruction code/Writing data
Error related to Position instruction data/P oint table No.
Error related to Speed instruction data/Point table No.
Code No. Error Details
0 Normal answer Instruction was completed normally.
1 Code error The monitor code not in the specifications was set.
Read/write of the point table of No.255 or later was set.
2 Parameter point table
selection error
The parameter No. disabled for reference was set.
3 Write range error An attempt was made to write the parameter or point table data outside
the setting range.