3 - 38
3. CC-LINK COMMUNICATION FUNCTIONS
3.6.3 Remote register-based position/speed setting
The functions in this section are usable when Positio n/speed specifying system selection (RY(n+2)A) is ON
(remote register-based position/speed specifying system is selected) with 2 stations occupied.
The position command/speed command necessary for positioning can be selected by parameter No.PC30
setting as indicated below.
Set value
0
1
2Set the position data. Specify the point table N o.
Set the servo motor speed.
Specify the point table No.
Position command Speed command
Parameter No.PC30
(1) When setting the point table No.
Specify the point table No. stored in the servo amplifier and execut e positioning.
Preset " 0" (initial value) in parameter No.PC30 to enable point table No.-setting operation.
Point table No.
(RWwn+4)
Position instruction
execution
completion
(RX(n+2)0)
Forward/reverse
rotation start
(
RYn1 RYn2
)
Position instruction
demand
(RY(n+2)0)
Point table No.
designation
6ms
ON
OFF
ON
OFF
ON
OFF
(Note) Data reserved
Respond code
(RWrn+2)
Note. This data is stored into RAM of the servo amplifier. Hence, the data is cleared when power is switched off.
Set the point table No. to point table No. (RWwn+4) and turn Position instruc tion demand (RY(n+2)0) to
ON.
Turning RY(n+2)0 to ON stores the position block No. into RAM of the servo amplifier.
When the data is stored, Position instruction ex ecution completion (RX(n+2)0) turns to ON.
If data outside the setting range is set to Position blo ck No. (RWwn+4), the error code (refer to section
3.5.5) is set to respond code.
Turn Forward rotation start (RYn1)/Reverse rota tion start (RYn2) to ON after Position instruction executio n
completion (RX(n+2)0) has turned to ON.