1 - 6
1. FUNCTIONS AND CONFIGURATION
(2) Operation using CC-Link communication functi ons and external input signals
(a) Operation
Using parameter No.PD06 to PD08 and parameter No.PD12 , PD14, input devices can be assigned to
the external input devices of CN1A and CN1B . The signals assigned to the external input s ignals cannot
be used with the CC-Link communication functions. Output devices can be used with the CN6
connectors and CC-Link communication functions s imultaneously.
(b) Configuration
CN2
CN6
CN1
CNP3 CNP3
CN2
CN6
CN1
External I/O
signal
External I/O
signal
Servo amplifier
(Axis 1)
Servo amplifier
(Axis 2)
To the next axis
Programmable controller
CC-Link master unit