6 - 2
6. PARAMETERS
6.1.2 Parameter write inhibit
Parameter
No. Symbol Name
Initial
value Unit Setting range
PA19 *BLK Parameter write inhibit 000Ch Refer to the text.
POINT
This parameter is made valid when power is switched off, then on af ter
setting.
In the factory setting, this servo amplifier allows changes to the basic setting parameter, gain/filter par ameter
and extension setting parameter settings. W ith the setting of parameter No.PA19, write can be disabled to
prevent accidental changes.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No.PA19. Operation can be perform ed for the parameters marked .
Parameter No.PA19
setting Setting operation
Basic setting
parameters
No.PA
Gain/Filter
parameters
No.PB
Extension setting
parameters
No.PC
I/O setting
parameters
No.PD
Reference
0000h Write
Reference
000Bh Write
Reference 000Ch
(initial value) Write
Reference
100Bh Write Parameter No.
PA19 only
Reference
100Ch Write Parameter No.
PA19 only