6 - 30
6. PARAMETERS
6.4.2 Detail list
No. Symbol Name and function Initial
value Unit Setting
range
PD01 *DIA1 Input signal automatic ON selection 1
Select the input devices to be automatically turned ON.
part is for manufacturer setting. Do not set the value by any means.
0
0
0
Initial value
BIN HEX
Device name
0
0
Initial value
BIN HEX
Proportion control (PC)
Initial value
BIN HEX
Servo-on (SON) 0
0
0
0
Forward rotation
stroke end (LSP)
0
0
0
00
0
Reverse rotation
stroke end (LSN)
BIN 0: Used in CC-Link or as ext ernal
input signal.
BIN 1: Automatic ON
Device name
Device name
0
Initial value
BIN HEX
0
0
0
0
Forced stop (EMG)
Device name
For example, to turn ON SON, the setting is " 4".
0000h Refer to
name and
function
column.
PD02 For manufacturer setting
Do not change this value by any means.
0000h