16 - 83
16. INDEXER POSITIONING OPERATION
No. Symbol Name and function Initial value Unit Setting
range
PB14 NHQ1 Notch shape selection 1
Used to selection the machine resonance suppression filter 1.
Notch depth selection
Setting value Depth Gain
0-40dBDeep
1-14dB
2 -8dB
3 -4dBShallow
Notch width
Setting value Width
02Standard
13
24
35Wide
00
to
to
Setting parameter No.PB01 (filter tuning mode 1) to " 1" automatically
changes this parameter.
When the parameter No.PB01 setting is " 0", the setting of this parameter
is ignored.
0000h Refer to
name and
function
column.
PB15 NH2 Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter 2.
Set parameter No.PB16 (notch shape selection 2) to " 1" to make this
parameter valid.
4500 Hz 100
to
4500
PB16 NHQ2 Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
Notch depth selection
Setting value Depth Gain
0-40dBDeep
1-14dB
2-8dB
3-4dBShallow
to
Notch width
Setting value Width
02Standard
13
24
35Wide
to
0
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
0000h Refer to
name and
function
column.
PB17 Automatic setting parameter
The value of this parameter is set according to a set value of parameter
No.PB06 (Ratio of load inertia moment to servo motor inertia moment).