TConnect View

Close - you can close the SEL viewer.

Save As - dumps the SEL data to a file in either binary raw or verbose text format. The binary file may be retrieved later. Selecting this option lets you specify a filename to which the data is saved. The default filename is "SELLOG.DAT." If there is no data, an error message is displayed.

Exit - exits the EMP.

TConnect View

SEL Information - displays SEL summary information as returned by the server.

All Events - displays all events in the SEL.

By Sensor Type - shows all events in the SEL generated by a specific sensor type such as voltage, temperature, etc.

By Event - displays all the events in the SEL of a particular type; for example, by memory or threshold. A pop-up menu lets you select the event type to display. This pop-up menu displays all the event

Ttypes that may be generated by the particular hardware.

Settings - you can change several operating parameters for the SEL viewer. This menu displays the following suboptions:

Display HEX/Verbose - toggles between HEX mode and interpreted mode of displaying SEL records.

Output Text/Binary - determines whether SEL data is saved to the file in binary format or verbose format.

TWindow - gives options for displaying currently open windows.

Help - provides version information for the SEL viewer and provides help topics on the EMP.

SDR Viewer

The SDR viewer lets you view the Sensor Data Records retrieved from the SDR repository. Options available through the SDR viewer are:

view all SDR records

view SDR entries by SDR type

view SDR summary info

Tset SDR display mode to either Hex or verbose mode close the SDR viewer

C-14 Emergency Management Port