Using the Console Interface

Table 3-24. Port Mirroring Configuration Screen Fields (continued)

Field

Description

 

 

 

Monitor Unit/Port

Indicates the port number (of the specified unit) that is designated as the monitor

 

port.

 

 

Default

Zero-length string

 

Range

1 to 8 / 1 to 28 (depending on model type)

Unit/Port X

Indicates one of the ports (of the specified unit) that will be monitored by the

 

designated port monitor when one of the port-based monitoring modes is selected.

 

This port will be monitored according to the value X in the Monitoring Mode field (see

 

Table 3-25).

 

 

Default

Zero-length string

 

Range

1 to 8 / 1 to 28 (depending on model type)

Unit/Port Y

Indicates one of the ports (of the specified unit) that will be monitored by the

 

designated port monitor when one of the port-based monitoring modes is selected.

 

When installed as a standalone switch, the screen does not display the (Unit/) field

 

designation. This port will be monitored according to the value Y in the Monitoring

 

Mode field (see Table 3-25).

 

Default

Zero-length string

 

Range

1 to 8 / 1 to 28 (depending on model type)

Address A

Indicates the MAC addresses that will be monitored by the designated port monitor

 

when one of the address-based monitoring modes is selected. This port will be

 

monitored according to the value “Address A” in the selected Monitoring Mode field

 

(see Table 3-25). Users can enter the MAC address from this screen or from the MAC

 

Address Table screen. The entry is displayed and can be modified by either screen

 

(see “MAC Address Table” on page 3-21).

 

Default

00-00-00-00-00-00 (no MAC address assigned)

 

Range

00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

Address B

Indicates the MAC addresses that will be monitored by the designated port monitor

 

when one of the address-based monitoring modes is selected. This port will be

 

monitored according to the value “Address B” in the selected Monitoring Mode field

 

(see Table 3-25). Users can enter the MAC address from this screen or from the MAC

 

Address Table screen. The entry is displayed and can be modified by either screen

 

(see “MAC Address Table” on page 3-21).

 

Default

00-00-00-00-00-00 (no MAC address assigned)

 

Range

00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

 

 

 