Troubleshooting

Table 4-1. BayStack 410-24T Switch LED Descriptions (continued)

Label

Type

Color

State

Meaning

 

 

 

 

 

 

 

Green

On

The switch is connected to the upstream unit’s Cascade A

 

 

 

 

In connector.

 

 

Yellow

On

The Cascade A Out connector (CAS Up) for this switch is

 

 

 

 

looped internally (wrapped to the secondary ring).

 

 

Yellow

Blinking

Incompatible software revision or unable to obtain a unit

 

 

or

 

ID (Renumber Stack Unit table full). The unit is on the ring

 

 

Green

 

but cannot participate in the stack configuration.

CAS Dwn

Stack mode

 

Off

The switch is in standalone mode.

 

 

Green

On

The switch is connected to the downstream unit’s

 

 

 

 

Cascade A Out connector.

 

 

Yellow

On

The Cascade A In connector (CAS Dwn) for this switch is

 

 

 

 

looped internally (wrapped to the secondary ring).

 

 

Yellow

Blinking

Incompatible software revision or unable to obtain a unit

 

 

or

 

ID (Renumber Stack Unit table full). The unit is on the ring

 

 

Green

 

but cannot participate in the stack configuration.

Base

Base mode

Green

On

The switch is configured as the stack base unit.

 

 

 

Off

The switch is not configured as the stack base unit (or is

 

 

 

 

in standalone mode).

 

 

 

Blinking

Stack configuration error: Indicates that multiple base

 

 

 

 

units or no base units are configured in the stack.

 

 

Yellow

On

This unit is operating as the stack configuration’s

 

 

 

 

temporary base unit. This condition occurs automatically

 

 

 

 

if the base unit (directly downstream from this unit) fails.

 

 

 

 

If this happens, the following events take place:

 

 

 

 

• The two units directly upstream and directly

 

 

 

 

downstream from the failed unit automatically wrap

 

 

 

 

their cascade connectors and indicate this condition

 

 

 

 

by lighting their Cas Up and Cas Dwn LEDs (see Cas

 

 

 

 

Up and Cas Dwn description in this table).

 

 

 

 

• If the temporary base unit fails, the next unit directly

 

 

 

 

downstream from this unit becomes the new

 

 

 

 

temporary base unit. This process can continue until

 

 

 

 

there are only two units left in the stack configuration.

 

 

 

 

(continued)