Nortel Networks 10BASE-T manual Vlan Broadcast Domains Within the Switch

Models: 10BASE-T

1 330
Download 330 pages 13.91 Kb
Page 77
Image 77

Introduction to the BayStack 410-24T Switch

S1

 

 

 

 

 

 

 

 

VLAN 3

 

 

 

 

 

VLAN 2

VLAN 1

 

Port 2

Port 4

Port 10

Port 8

Port 6

Port 11

PVID = 2

 

 

PVID = 3

PVID = 1

 

V2

V2

V2

V3

V1

V2

Key

VLAN 1 (PVID = 1)

VLAN 2 (PVID = 2)

VLAN 3 (PVID = 3)

BS41024A

Figure 1-26. VLAN Broadcast Domains Within the Switch

The broadcast domain for each of the VLANs shown in Figure 1-26 is created by configuring VLAN port memberships for each VLAN and then configuring each of the ports with the appropriate PVID/VLAN association:

Ports 8, 6, and 11 are untagged members of VLAN 1.

The PVID/VLAN association for ports 6 and 11 is: PVID = 1.

Ports 2, 4, 10, and 8 are untagged members of VLAN 2.

The PVID/VLAN association for ports 2, 4, and 10 is: PVID = 2.

Ports 2, 4, 10, 8, 6, and 11 are untagged members of VLAN 3. The PVID/VLAN association for port 8 is: PVID = 3.

The following steps show how to use the VLAN configuration screens to configure the VLAN 3 broadcast domain shown in Figure 1-26.

309985-C Rev 00

1-47