Using the Console Interface

 

 

Table 3-19.

Port Configuration Screen Fields (continued)

 

 

 

Field

Description

 

 

 

Status

Allows you to disable any of the switch ports. You can also use this field to control

 

access to any switch port.

 

Default

Enabled

 

Range

Enabled, Disabled

Link

A read-only field that indicates the current link state of the corresponding port, as

 

follows:

 

Up: The port is connected and operational.

Down: The port is not connected or is not operational.

LnkTrap

Allows you to control whether link up/link down traps are sent to the configured trap

 

sink from the switch.

 

Default

On

 

Range

On, Off

Autonegotiation

When enabled, sets the corresponding port speed to match the best service provided

 

by the connected station (up to 100 Mb/s in full-duplex mode when a 10/100 MDA is

 

installed). This field is disabled for all fiber optic ports.

 

Default

Enabled

 

Range

Enabled, Disabled

Speed/Duplex1

Allows you to manually configure any port to support an Ethernet speed of 10 Mb/s in

 

half- or full-duplex mode. When a 10/100 MDA is installed, you can manually

 

configure the MDA ports to support 10 Mb/s or 100 Mb/s in half- or full-duplex mode.

 

Default

10Mbs/Half (when Autonegotiation is Disabled)

 

Range

10Mbs/Half, 10Mbs/Full, 100Mbs/Half, 100Mbs/Full

 

 

 

1 Fiber optic ports can only be set to 100Mbs/Half or 100Mbs/Full.

High Speed Flow Control Configuration

The High Speed Flow Control Configuration screen (Figure 3-23) allows you to set the port parameters for any gigabit MDA that may be configured in a stack configuration.

Note: The BayStack 410-24T switch does not support gigabit MDAs; however, this screen will appear if the BayStack 410-24T switch is part of a stack configuration, and only if a gigabit MDA is installed in any stack unit.

309985-C Rev 00