Appendix

 

 

 

Code

Cause

Definition

 

 

 

97

Message type

The equipment received a message of a type that is

 

nonexistent or not

invalid or not supported. This code indicates either a

 

implemented

problem with the remote configuration or a problem with

 

 

the local D channel.

 

 

 

98

Message

The equipment received a message that is not valid in

 

incompatible with

the current call state. Cause 98 is usually due to a

 

call state or

D-channel error. If this error occurs systematically,

 

message type

report it to your ISDN service provider.

 

nonexistent

 

 

 

 

99

Information element

The equipment received a message that includes

 

nonexistent or not

information elements which were not recognized. This is

 

implemented

usually due to a D-channel error. If this error occurs

 

 

systematically, report it to your ISDN service provider.

 

 

 

100

Invalid information

The equipment received a message that includes

 

element contents

invalid information in the information element. This is

 

 

usually due to a D-channel error.

 

 

 

101

Message not

The remote equipment received a message that does

 

compatible with call

not correspond to the current state of the connection.

 

state

This is usually due to a D-channel error.

 

 

 

102

Recovery on timer

A time-out has triggered an error-handling (recovery)

 

expiry

procedure. This problem is typically temporary.

 

 

 

111

Protocol error,

An unspecified D-channel error when no other standard

 

unspecified

cause applies.

 

 

 

127

Interworking,

An event occurred within a network that does not

 

unspecified

provide causes for the action that it takes. The precise

 

 

problem is unknown.

 

 

 

145

ISDN layer 1 and/or

User needs to check cabling, ISDN adapter status and

 

2 link not established

network connections.

 

 

 

146

ISDN layer 3

There is either a switch protocol error, or (in the United

 

connection to the

States or Canada) a SPID assignment problem.

 

ISDN switch/network

 

 

inactive

 

 

 

 

255

ISDN command

The ISDN signaling code has encountered an error

 

processing error

processing an ISDN action. ISDN adapter busy-wait

 

 

and retry.

 

 

 