MGC Web Server Manager User’s Guide
2-13
Connecting/Disconnecting to/from an MCU
Once the MCUs are defined in the database, you can connect to an MCU.
This step is mandatory in order to run conferences, and it can be performed
only after the MGC Web Server Manager is connected to the MGC Web
Server. If all MCUs or the MGC Web Server are disconnected, remote users
cannot run conferences via the Web. For more details on how to define a new
MCU, see Chapter 5, “Defining an MCU” on page 5-1.

Connecting to an MCU

To connect to an MCU:
1. In the Browser area, click the Server icon to display the list of MCUs
currently defined in the MGC Web Server Manager application.
The MCUs list contains all the MCUs currently defined in all the
databases set in the Web Server Manager application. If the same MCU
is defined in two databases, it will appear twice in the MCUs list.
2. In the Status area, right-click the MCU icon and then click Connect.
The system connects to the selected MCU. The MCU status that appears
in the Status area changes first to Connecting, during the connection
procedure and then to Normal at the end of the connection procedure.