Contents
Powerware 9315 UPS 500-750 kVA
Consignes DE Sécurité Importantes Conserver CES Instructions
Special Symbols
This page intentionally left blank
Table of Contents
10-1
11-1
12-1
13-1
Warranty
Product Specifications
Appendix a Installation Reference
14-1
List of Figures
Figure A‐10. Securing Cables
Chapter Introduction
‐1. Typical Powerware 9315 500-750 kVA UPS System
UPS Features
Options and Accessories
Monitoring and Communication
Basic System Configurations
Safety Warnings
Conventions Used in This Manual
For More Information
Icon Description
Getting Help
This page intentionally left blank
Section
Page
Creating an Installation Plan
Chapter UPS Installation Plan and Unpacking
Preparing Your Site
Environment Considerations
Inspecting and Unpacking Each Cabinet
Preparing for Wiring the UPS System
UPS Installation Plan and Unpacking
This page intentionally left blank
Preliminary Installation Information
Chapter Installing the UPS System
Single Module Installation
Installing UPS Internal Power and Control Wiring
Unloading the UPS Cabinets from the Pallet
Installing UPS External Power and Control Wiring
Multi‐Module Installation
Installing UPS External Power and Control Wiring
Installing Output/Inverter Customer Connections
Installing Input/Rectifier Customer Connections
Installing Accessories
Initial Startup
Completing the Installation Checklist
Installation Checklist
Installing the UPS System
This page intentionally left blank
‐1. Remote Battery Disconnect Enclosure
Chapter Installing a Remote Battery Disconnect
‐2. Remote Battery Disconnect Circuit Breaker Ratings
‐1. Remote Battery Disconnect Power Terminations
Tightening Torque Bolt Size
UPS Model Circuit Breaker Rating DC Voltage
‐1. Repo Wire Terminations
Repo Installation
Wire Size
Chapter
Repo Operation
Activated
Deactivated
‐1. Optional Monitoring Accessories
Chapter Installing Optional Accessories
Number and Type of Accessories Permitted
Slot
‐1. RMP
Installing an RMP
‐2. Terminal Block Bracket
From RMP a To UPS Remarks
‐2. RMP Wire Terminations
‐3. RIM
Installing an RIM
From RIM a To UPS Remarks
‐3. RIM Wire Terminations
‐5. SCM
Installing an SCM
From SCM a To UPS Remarks
‐4. SCM Wire Terminations
‐7. SCM TB2
Installing X-Slot Cards
Operation
Page
Chapter Understanding UPS Operation
Battery String
Input/Rectifier
Output/Inverter
Operating Modes
‐2. Path of Current Through the UPS in Normal Mode
Normal Mode
‐3. Path of Current Through the UPS in Bypass Mode
Bypass Mode
‐4. Path of Current Through the UPS in Battery Mode
Battery Mode
This page intentionally left blank
‐1. UPS Control Panel
Chapter Using the Control Panel
‐2. LCD Screen
Using the LCD Screen
Adjusting the Contrast
Using the Pushbuttons
Reading the Status Indicators
Using the Menu Options
Normal Battery Bypass Alarm Standby
‐4. System Meters Screen
System Meters Screen
‐5. Load Amps Meters Screen
Load Amps Meters Screen
‐6. Software Versions Screen
Software Versions Screen
‐7. Event History Log Screen
Event History Log Screen
‐8. Active System Events Screen
Active System Events Screen
‐9. Unit Statistics Screen
Unit Statistics Screen
‐10. Mimic Screen
Mimic Screen
‐11. Time Setup Screen
Time Setup Screen
‐12. Port Setup Screen
Port Setup Screen
This page intentionally left blank
Chapter UPS Operating Instructions
UPS Controls and Indicators
Control Panel
UPS Circuit Breakers
Emergency UPM Off
Starting the UPS
Starting the UPS in Bypass Mode
Transferring to Normal Mode
Transferring to Bypass Mode
Using the UPS Emergency UPM Off Pushbutton
Transferring to Bypass and Shutting Down the UPS
Shutting Down the UPS and Critical Load
Resetting the UPS System after an Emergency UPM Off
Using the UPS Emergency UPM Off Pushbutton
This page intentionally left blank
Chapter Using Features and Options
Building Alarm Monitoring
General Purpose Relay Contacts
Optional Remote Monitor Panel
System Normal
‐2. RIM
Optional Relay Interface Module
‐3. SCM
Optional Supervisory Contact Module
10-6
Chapter Responding to System Events
System Event Indicators
System Event Horns
System Event Messages
Responding to System Events
Pin Number Symbol Function Comments
Connecting Equipment to a Serial Port
Chapter Communication
Locating the Customer Interface Panel
‐2. Port 2 DB‐25 ‐2. Pin Assignments for Port 2 DB‐25
‐3. Setup Serial Port 1 Screen
Configuring the Serial Ports
Rate
Modes
‐3. Options Available for Each Communication Port
Port Options
Data/Stop
Default Settings
Handshaking
Save
Printing Selected Information
Terminal Mode
‐4. Event History Log
Entire Log Ctrl+P
System Information Printout Ctrl+A
Meters Printout Ctrl+M
System Configuration Mode Main Menu
System Configuration Mode
Program Building Alarms
Enable/Disable Default Functions
Customize Alarm Messages
Program Unit Name
Change Password
WK DAY MON Hrmn
Battery Test Setup
Computer Mode
Calibration Mode
Remote Monitor Mode
Modify Low Battery Time
ENotify Service
ENotify Service Features
Installing eNotify Service
Remote Notification
‐6. Optional X-Slot Cards
Slot Cards
Chapter Maintaining the UPS System
Important Safety Instructions
Daily Maintenance
Performing Preventive Maintenance
Monthly Maintenance
Annual Maintenance
Recycling the Used Battery or UPS
Maintenance Training
Battery Maintenance
13-4
Chapter Product Specifications
Model Numbers
UPS System Input
UPS System Output
Environmental Specifications
Limited Factory Warranty
Chapter Warranty
Warranty
Physical Features and Requirements
Appendix a Installation Reference
Table A. Equipment Weight
Table B. UPS Cabinet Clearances
400/400
Figure A‐1. Typical Powerware 9315 500-750 kVA UPS System
Figure A‐2. Inverter/Rectifier Cabinet PCM 1 Dimensions
Figure A‐3. Inverter/Rectifier Cabinet PCM 1 Dimensions
Figure A‐4. Output/Inverter Cabinet PCM 2 Dimensions
Figure A‐5. Output/Inverter Cabinet PCM 2 Dimensions
Figure A‐6. MBC PCM 3 Dimensions
Figure A‐7. MBC PCM 3 Dimensions
Table D. Powerware 9315 UPS System Oneline Configurations
UPS System Oneline Configurations
Oneline Drawing
Vin / Vout System Type
Power Control Module PCM To Ground MBC
UPS Output to Critical Load PHASE, 3 or 4 Wire
Power Wiring Installation Notes
Basic Unit Rating Units Rating 50/60 Hz
DC Input from Battery to UPS
Input and Output Voltage
AC Input to UPS Rectifier 0.95 Min. pF
PW9315-750/500 at 0.8 Lagging pF Load
PW9315-750/600 at 0.8 Lagging pF Load
SBM
UPS Model Voltage Terminal Number of Wires Minimum Conduit
Table I. Power Cable Conduit Requirements
Part Size Quantity Manufacturer
Figure A‐10. Securing Cables
Input Voltage Rating
Table K. Maximum Input Circuit Breaker Ratings
Table L. Maximum Output Circuit Breaker Ratings
Table N. Battery Shunt Trip Wiring Requirements
Table M. Maximum DC Input Circuit Breaker Ratings
Output Voltage Rating
Figure A‐11. CB2TB to DC Source Disconnect Device
Figure A‐12. Inverter/Rectifier Cabinet PCM 1 Terminals
Location of UPS Terminals
Figure A‐13. Inverter/Rectifier Cabinet PCM 1 Terminals
Figure A‐14. Output/Inverter Cabinet PCM 2 Terminals
Figure A‐15. Output/Inverter Cabinet PCM 2 Terminals
Figure A‐16. MBC PCM 3 Terminals
Figure A‐17. MBC PCM 3 Terminals
CUSTJ4 Terminal Name Description
Customer Interface Wiring Notes
Battery I/O Board
Battery Terminal Board
RS-485
Panel X-SLOT
Custtb Terminal
CUSTJ2 Terminal
CUSTJ4
Table Q. MBC Customer Interface Connections
MBC I/O Board
Typical Repo
Switch
Front View Contact Block Back View, Faceplate Removed
Figure A‐25. Eaton Repo Switch
Figure A‐26. RMP Dimensions and Mounting Details
RMP Dimensions and Mounting Details
Figure A‐27. RIM Dimensions and Mounting Details
RIM Dimensions and Mounting Details
Figure A‐28. RIM Dimensions and Mounting Details
Figure A‐29. SCM Dimensions and Mounting Details
SCM Dimensions and Mounting Details
Figure A‐30. Battery Disconnect Switch Dimensions
Battery Disconnect Switch Dimensions
Page
164201244E
Top
Page
Image
Contents