Performance Verification

Amplitude, Offset Accuracy and Rise Time Tests (for option 02)

These procedures check the accuracy of the AWG710 Arbitrary Waveform

Generator option 02 outputs; amplitude and offset.

Check Amplitude

 

 

and

 

 

DC Offset

 

 

Equipment

A 504W BNC4coaxial cable, a 504W4precision terminator, an

 

 

required

SMA￿Ma￿5BNC￿Fe￿4adapter, BNC ￿female￿5to5dual banana adapter, and

 

 

a digital multimeter ￿DMM￿.

 

 

 

 

Prerequisites

The AWG710 option 02 Arbitrary Waveform Generator must meet the

 

 

prerequisites listed on page￿4-8.

 

 

 

Do the following steps to install the test hookup and set the test equipment controls:

1.Use a 50 W BNC coaxial cable, an SMA(Ma)-BNC(Fe) adapter, a 50 W precision terminator, and a BNC-to-dual banana adapter to connect the AWG710 Arbitrary Waveform Generator CH1 output to the DMM input connector (see Figure 4±12).

AWG710 option 02 Arbitrary Waveform Generator

50 W BNC4coaxial cable

CH14output4connector

+4SMA￿Male￿5BNC￿Female￿ adapter +4BNC 50 W4precision terminator +450 W4BNC coaxial cable

Input4connector +4BNC5to5dual banana adapter +450 W BNC4coaxial4cable

DMM

Figure 4-12: Option 02 output amplitude accuracy initial test hookup

2.Set the DMM controls as follows:

Mode . . . . . . . . . . . . . . . . . . . . . . . . . .

VDC

Range . . . . . . . . . . . . . . . . . . . . . . . . .

2 V

Input . . . . . . . . . . . . . . . . . . . . . . . . . .

Front

AWG710 Service Manual

4-31