Removal and Installation Procedures
Line Fuse and Line Cord You will need a
WRNING To avoid electrical shock, be sure that the power cord is disconnected from the socket before checking the line fuse.
1.Orient the generator so the bottom is on the work surface and the rear is facing you.
2.Disconnect the line cord from the rear panel connector and main power.
3.If you are servicing the line fuse, do the next step; if you are servicing the line cord, skip to step 5.
4.Find the fuse cap on the rear panel. See Figure 6±7. Remove the fuse cap by turning it counterclockwise using a
5.Find the line cord on the rear cover. See Figure 6±7. Pull the line cord to complete the removal. Do the procedure in reverse order to install.
6.Do steps 4 and 5 in reverse order to install the line cord and line fuse.
Line Fuse
Fuse Cap
Figure
AWG710 Service Manual |