Performance Verification
CH1 input impedance . . . . . . . . . . | 50 W |
CH2 input impedance . . . . . . . . . . | 1 M W |
Horizontal |
|
Sweep . . . . . . . . . . . . . . . . . . . . . | 1 ms/div |
Trigger |
|
Source . . . . . . . . . . . . . . . . . . . . . | CH1 |
Coupling . . . . . . . . . . . . . . . . . . . . | DC |
Slope . . . . . . . . . . . . . . . . . . . . . . | Positive |
Level . . . . . . . . . . . . . . . . . . . . . . | +100 mV |
Mode . . . . . . . . . . . . . . . . . . . . . . | Auto |
a.Set the function generator controls as follows:
Function . . . . . . . . . . . . . . . . . . . . . . . . | DC |
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . | Continuous |
Output . . . . . . . . . . . . . . . . . . . . . . . . . | Off |
b.Push UTILITY
c.Push SETUP
d.Load the TRIG.WFM file.
Refer to Loading Files on page 4±10 for file loading procedures.
4.Push the RUN and CH1 OUT buttons.
The LEDs above the RUN button and CH1 output connector are on.
5.Set the trigger level to 5 V by the following substeps:
a.Push SETUP
b.Push 5 and ENTER keys in this order.
6.Set the trigger input signal level to 4.65 V by the following substeps below:
a.Turn on the function generator output.
b.Select offset by pressing the OFFSET button of the function generator.
c.Set the DC waveform High level to 4.65 V by using the arrow keys.
d.Check that no waveform is displayed on the oscilloscope as shown in Figure 4±16.
AWG710 Service Manual |