![](/images/backgrounds/275910/275910-267141x1.png)
Performance Verification
Figure
c.Open SW4 of the ground closure to degenerate the event signal.
d.Verify that the oscilloscope displays the waveform in Figure 4±21.
11.Retain the test hookup and control settings.
Check Strobe Input Use the test hookup and oscilloscope settings from the Check Event Input with Strobe Off test.
1.Follow the substeps below to set the AWG710 Arbitrary Waveform Generator controls and select the sequence file:
a.Push UTILITY
b.Load the PT_STROB.SEQ file.
Refer to Loading Files on page 4±10 for file loading procedures.
c.Push SETUP
2.Push the RUN and CH1 OUT buttons.
The LEDs above the RUN button and CH1 output connector are on.
3.Check the EVENT IN connector strobe pin input:
a.Verify that the waveform displayed on the oscilloscope has the same amplitude as shown in Figure 4±26.
AWG710 Service Manual |