Texas Instruments MATRIX 3000, DW30 Error Codes f, Code Description, General, Lamp Failures

Models: DW30 MATRIX 3000

1 143
Download 143 pages 26.11 Kb
Page 96
Image 96
Error Codes f

Section 3: Operation

Error Codes f

Code Description

GENERAL

12Software bug. Contact dealer/factory.

13Flash memory corrupted. Download new software.

14Engineering only programming is complete. Call Christie, replace TIPM.

15Attempting to download code without being in boot mode

16Invalid interrupt. Power off/on. If it persists, contact dealer/factory.

17Forced boot mode. Keys held down too long.

18Attempting to program boot mode without jumper

LAMP FAILURES

21

Lamp compartment too hot

25Lamp 1 not installed

26Lamp 1 Interlock: door open, lamp not installed

27Unable to turn lamp 1 ON

28Lamp 1 shut off unexpectedly

29Lamp 1 driver overheated

2A

Lamp 1 driver operation error (e.g. too hot can’t start)

2C

Lamp 1 driver UART communications failure

30Lamp 2 not installed

31Lamp 2 door open

32Unable to turn lamp 2 ON (unknown reason)

33Lamp 2 shut off unexpectedly

34Lamp 2 driver overheated

35Lamp 2 driver reports operation error (e.g. too hot can’t start)

36Lamp 2 driver UART communications failure

37Lamp Watchdog Tripped – Unless lamps turn on again after 3 minutes, assume software hung.

POWER AND COOLING

41Lamp 1 driver Vcc to low

42Color wheel 1 stopped for at lease one second

44Lamp 2 driver Vcc too low

45Color wheel 2 stopped for at least one second

4C

Projector shutdown due to critical error

51

TIPM fan failed

53

Main blower failed

56Engine fan failed

57Lamp 1 driver fan failed

58Lamp 1 fan failed

59Lamp 2 driver fan failed

5A

Lamp 2 fan failed

TIPM (image processor)

60Boot code CRC failed

61Unable to program the DigMux PLD

62Unable to program the Control PLD

63Unable to program the BUBKS PLD

64Unrecognized ROM type

65Write to flash ROM failed

66General image processor failure

67Downloaded code will not fit in the ROMs

68Communication problem with scaler on image processor

BUILT-IN or EEPROM

70

71

72

73

Unable to access the EEPROM on the built-in keypad

EEPROM memory re-initialization (built-in keypad)

Unable to access the EEPROM on the lamp module

Unable to access the EEPROM on the Back End Board

BACK END BOARD

80Unable to detect Back End Board

81Unable to program a device on the programming bus

82TI flash download failure – not started

83TI flash download failure – partial write

84TI flash download failure – checksum read

85TI – I2C write failure

86Communications failure

 

BACKPLANE or OPTIONAL INTERFACE MODULE

 

 

A0

Unable to program the Option Card

 

 

A1

Unable to power the Option Card

 

 

A2

Unable to program the Backplane module

 

 

A3

Unable to program the Warp Module

 

Clear system errors with Exit

Exit . If you encounter a system error, try resetting the projector by powering it off and on

again (wait at least 90 seconds and allow for proper cooling). For detailed information, monitor the RS232 IN port. Contact dealer/factory if error persists and if a code appears that is not listed.

013-100149-02 Rev. 1 (01/07)

Christie DS+60/DW30/Matrix 3000 User’s Manual 3-69

Page 96
Image 96
Texas Instruments MATRIX 3000 Error Codes f, Code Description, General, Lamp Failures, Power And Cooling, Back End Board