Chapter 5. Using the Terminal Menu
This alarm... | Means this... |
|
|
D Channel Sync | HDLC framing is operational on PRI D channel. |
This indication only applies when operating in PRI | |
| mode. |
|
|
Receive Level | Indicates the strength of the signal received on the |
(Rx Level) | port. |
|
|
DS0 Status Read security: 5
Indicates usage on a DS0 basis for each port. These options are
DS0 status... | Means this... |
|
|
* | Inactive |
|
|
A | Active call on this DS0 |
|
|
D | Active D Channel DS0 |
|
|
M | Maintenance DS0 |
|
|
N | Dedicated DS0 |
|
|
O | Off hook Detected |
|
|
R | Ringing Detected |
|
|
Sig Status Read security: 5
Indicates signaling of all 24 DS0s. The A/B bits for Rx and Tx DS0s are shown for each port.
Performance: Current
Write security: 4; Read security: 5
The performance fields – either current, 15 minute total, or 24 hour total – provide status on key performance measures as specified in ANSI T1.403 and AT&T TR54016 for each of the four T1/PRI ports. All of these options (except CLR) are
Field... | Provides this status information... |
|
|
Prt | Displays the port number. |
|
|
CLR | Clears information for the selected port. Press Enter when |
| the cursor is over this field to clear the data. |
|
|
ES | Errored Seconds. An ES is a second with one or more error |
| events OR one or more Out Of Frame events OR one or |
| more Controlled Slips. |
|
|
BES | Bursty Errored Seconds. A BES is a second with more than |
| one, but less than 320 error events. |
|
|
SES | Severely Errored Seconds. An SES is a second with 320 or |
| more error events OR one or more Out Of Frame events. |
|
|
SEFS | Severely Errored Frame Seconds. |
|
|
LOFC | Loss of Frame Count. |
|
|
CSS | Controlled Slip Seconds. |
|
|
ATLAS 800PLUS User Manual |
|