Chapter 5. Using the Terminal Menu
61200226L1-1 ATLAS_ 800PLUS User Manual 5-25
Empty
The system controller has not detected the presence of a module in the sys-
tem, nor has a module been manually enabled for this option slot.
Offline
The modules is installed but has been taken Offline by a user. The module is
still responding to controller polls.
Offline/No Response:
The module is installed but has been taken Offline by a user. The module is
not responding to polls.
Rev
Read security: 5
Displays the hardware revision of the ATLAS_ 800PLUS.
ATLA S_ 800PLUS Controller T1/PRI Submenu Items
The Modules/Menu submenu provides access to commands that allow you to
review the status of various options, change the configuration for general param-
eters, and initiate tests. This section only describes the menu options for the T1/
PRI controller port (the ATLAS_ 800PLUS base unit). For details on menu options
for individual modules, refer to the appropriate module manuals.
Controller Info
Read security: 5
Displays general information about the ATLAS_ 800PLUS Base Unit and T1/PRI
ports. The following items are read-only.
Alarm Status
Read security: 5
Displays any active alarms. These fields are read-only.
Part Num Displays the part number of the ATLAS_ 800PLUS.
PLL Status
(Phase Lock Loop)
Indicates whether the clock is locked to its specific source.
This alarm... Means this...
Prt Displays the port number.
Loss of Signal
(LOS)
No signal detected on port interface.
Red Alarm
(RED)
Not able to frame data received on the port.
Alternately referred to as Out of Frame (OOF).
Yel low Al ar m
(YELLOW)
Remote alarm indicator (RAI) being received on
port.
Blue Alarm
(BLUE)
Receiving unframed all ones from the port alarm