Chapter 5. Using the Terminal Menu
Empty
The system controller has not detected the presence of a module in the sys- tem, nor has a module been manually enabled for this option slot.
Offline
The modules is installed but has been taken Offline by a user. The module is still responding to controller polls.
Offline/No Response:
The module is installed but has been taken Offline by a user. The module is not responding to polls.
Rev
Read security: 5
Displays the hardware revision of the ATLAS 800PLUS.
ATLAS 800PLUS Controller T1/PRI Submenu Items
The Modules/Menu submenu provides access to commands that allow you to review the status of various options, change the configuration for general param- eters, and initiate tests. This section only describes the menu options for the T1/ PRI controller port (the ATLAS 800PLUS base unit). For details on menu options for individual modules, refer to the appropriate module manuals.
Controller Info
Read security: 5
Displays general information about the ATLAS 800PLUS Base Unit and T1/PRI ports. The following items are
Part Num | Displays the part number of the ATLAS 800PLUS. |
PLL Status | Indicates whether the clock is locked to its specific source. |
(Phase Lock Loop) |
|
Alarm Status
Read security: 5
Displays any active alarms. These fields are
This alarm... | Means this... |
|
|
Prt | Displays the port number. |
|
|
Loss of Signal | No signal detected on port interface. |
(LOS) |
|
|
|
Red Alarm | Not able to frame data received on the port. |
(RED) | Alternately referred to as Out of Frame (OOF). |
|
|
Yellow Alarm | Remote alarm indicator (RAI) being received on |
(YELLOW) | port. |
|
|
Blue Alarm | Receiving unframed all ones from the port alarm |
(BLUE) | indicator signal (AIS). |
|
|
| ATLAS 800PLUS User Manual |