Chapter 4. Front Panel Operation and Menu Structure
Show Results
This option displays the types of tests performed during a
Test... | Checks this... |
|
|
NVRAM | |
|
|
DSP RAM | Digital signal processor RAM |
|
|
RTC RAM | Real time clock RAM |
|
|
TDM MAP | TDM time slot mapping RAM |
|
|
DRAM | Dynamic program memory used for program execution |
|
|
Slot | Data path test to individual modules |
|
|
A RAM test failure indicates a controller board problem. If a slot fails, the module in the slot may have a problem,
Clear Results
This option resets the
If you clear the message log, you cannot retrieve the data.
Set Passcode (Front Panel)
The Set Passcode option provides security for front panel access. You can change or set the front panel passcode at any time or eliminate it altogether through the Set Passcode option. By default, the front panel does not have a passcode.
The passcode can only be entered by using numbers (any number except zero). After entering the desired passcode, press Enter. The prompt Verify Passcode displays. Enter the passcode again and press Enter.
Set a null passcode by pressing 0 and then pressing Enter. When the Verify Pass- word prompt displays, press 0 and Enter again. A null passcode grants unlimited access to front panel options.
Password Reset
You can create a list of system passwords with the terminal menus (see “Access Passwords” on page
Call ADTRAN technical support, and tell them the challenge number. They use this to generate a random response number. Enter this response number in the
RESPONSE # field, and ATLAS 800PLUS inserts a default password into the sys- tem password list. You can then use the new default password to log into the ter- minal menus.
ATLAS 800PLUS User Manual |
|