Appendix A. System Event Logging
A-2 ATLAS 800 PLUS User Manual 61200226L1-1
Table A-1. Source: System
Event Categor y Console Log
String
Front Panel
Display
System Cold Start – generated 5 seconds
after the completion of system initializa-
tion.
Normal Cold Start COLD START
SNMP Authentication Failure – generated
if the ATLAS receives an SNMP request
from an SNMP manager defined in the
ATLAS SNMP Communities list but with a
community name that does not match the
community name defined in the SNMP
Communities list.
Info SNMP Authenti-
cation Failure
AUTHEN FAIL
Module removed or not responding Warning Module Not
Responding
MODULE OUT -A
Module found Information Module Found MODULE FOUND
Console login failure – three consecutive
login attempts were attempted and failed
Minor Login Failure LOGIN FAILURE
An ATLAS 800 configuration file was
loaded into the system and was activated
Critical System Configu-
ration Uploaded
CONFIG
UPLOADED
The internal system temperature is too high Critical Internal Tempera-
ture Warning
TEMP WARN -A
The internal system temperature has
returned to norma
lCritical Internal Tempera-
ture Warning
Cleared
TEMP WARN -I
The primary power supply is present but is
not operating properly
Critical Main Power Sup-
ply Failure
PS1 WARNING -A
The primary power supply is operating
properly or has been removed
Critical Main Power Sup-
ply Failure
Cleared
PS1 WARNING -I
The backup power supply is present but is
not operating properly
Critical Backup Power
Supply Failure
PS2 WARNING -A
The backup power supply is operating
properly or has been removed
Critical Backup Power
Supply Failure
Cleared
PS2 WARNING -I