Chapter 9. SNMP Management

Table 9-5 describes the Total Alert Traps, which describe events that have occurred in the last 24-hour interval.

Table 9-5. Total Alert Traps

Total Alert

Severity

Description

 

 

 

adATLAS800TotalES

WARNING

the total interval errored second threshold has been

 

 

exceeded

 

 

 

adATLAS800TotalSES

WARNING

the total interval severely errored second threshold

 

 

has been exceeded

 

 

 

adATLAS800TotalSEFS

WARNING

the total interval severely errored framing second

 

 

threshold has been exceeded

 

 

 

adATLAS800TotalUAS

MAJOR

the total interval unavailable second threshold has

 

 

been exceeded

 

 

 

adATLAS800TotalCSS

WARNING

the total interval controlled slip second threshold has

 

 

been exceeded

 

 

 

adATLAS800TotalPCV

WARNING

the total interval path code violation has been

 

 

exceeded

 

 

 

adATLAS800TotalLES

WARNING

the total interval line errored second threshold has

 

 

been exceeded

 

 

 

adATLAS800TotalLCV

WARNING

the total interval line code violation threshold has

 

 

been exceeded

 

 

 

When one of the Total Alert thresholds is exceeded, the corresponding event bit is set to 1 in the adDS1TotalAlert variable in the DS1 Alert Table. When enabled, the ATLAS will send Alert Traps to each member of the Trap Destination List upon detecting status bit changes in adDS1TotalAlert. If you have previously set the corresponding enable bit = 1 in the adDS1TotalArm variable and adDS1AlertEnable = On, then the ATLAS will send an Alarm Trap message. A single Alert Trap message may report multiple event changes. The ATLAS clears the event bits after sending the Trap message or sending the response to a Get request for the adDS1TotalAlert variable.

The Current and Total Alerts described above are Near End events. The ATLAS will also support Current and Total Alerts for the Far End. Far End Alert Traps are generated upon status bit changes in adDS1FarCurrentAlert for Current Alerts and adDS1FarTotalAlert for Total Alerts. Current and Total Far End Alerts can be disabled by setting the corresponding enable bit = 0 in the adDS1FarCurrentArm and adDS1FarTotalArm variables, respectively. Far End Alert Traps can also be disabled by setting adDS1AlertEnable = Off.