Chapter 10. ADTRAN Utilities

Figure 10-3. Port Settings Dialog Box

Options Menu

Connect

Provides the options Transmit Wakeup and Transmit Refresh.

Refresh Screen

Redraws the screen.

Colors

These commands change the color of the background screen and text.

Local Echo and Auto Repeat

These options are the same as in the Telnet interface (see page 10-3 for details).

Capture Menu

The Capture option copies the text on the current VT-100 screen to the clipboard. You can open any word processor and paste the clipboard contents into the pro- gram. This option is helpful when debugging.

TFTP Server

The TFTP Server utility transfers ATLAS 800PLUS configuration files to and from a TFTP server. You can install this program on a PC running any version of Microsoft Windows. The configuration of an ATLAS 800 can be saved offline as a backup file. The saved file may also be used to send the same configuration to multiple ATLAS 800 units. Configuration file transfers are accomplished using the TFTP protocol (a TCP/IP user protocol) through the 10BaseT Ethernet port. The ATLAS 800 must have a valid IP address, subnet mask, and default gateway (if required), and must be connected to an Ethernet network before proceeding. Fig- ure 10-4 shows the TFTP Server interface.

10-4

ATLAS 800PLUS User Manual

61200226L1-1

Page 132
Image 132