Chapter 5. Using the Terminal Menu
If you clear the event log, you cannot retrieve the data.
Ethernet Port Read security: 5
Displays status information about the Ethernet port. These fields are
I/F Status
Indicates the current status of the 10BaseT port.
Tx Frames
Indicates the number of frames transmitted from the 10BaseT port since sys- tem startup.
Rx Frames
Indicates the number of frames received on the 10BaseT port since system startup.
Clear System LED
Write security: 3; Read security: 5
Changes the color of the system LED on the front panel from yellow (indicating a previous error) to green (OK). The system LED turns red if the ATLAS 800PLUS detects a major system failure. If the failure condition clears, the LED turns yellow and remains yellow to warn of the past failure.
System Alarms Read security: 5
Indicates the status of major system components. An asterisk (*) indicates activity for the items. These fields are
Temp Fail
The system’s internal temperature is outside normal limits.
PS1 Fail
The main power supply is not functioning correctly.
PS2 Fail
The backup power supply is not functioning correctly.
System Timing Source
Read Security 5
Indicates which timing source (primary or backup) is currently being used by ATLAS and if ATLAS is locked onto this source. If the display does not indicate locked, the ATLAS 800PLUS does not have a valid source of timing and cannot reliably transfer data. Review the current setting for system timing source in the System Config menu. See “Primary Timing Source” on page
System Resource Usage Write Security: 4 Read Security: 5
Indicates resource use (Analog Modems; Digital modems; Voice Compression).
ATLAS 800PLUS User Manual |
|