Appendix B | Troubleshooting | |
|
|
|
Table B-1. Troubleshooting
SYMPTOM | POSSIBLE CAUSES | TROUBLESHOOTING TIPS |
|
|
|
Modules seated improp- | Remove all modules and cycle power to the unit. | |
Fails | erly, module failure | If |
|
| report the results. If the |
|
| insert modules one at a time, running the self test |
|
| after installing each module. When an installed |
|
| module causes the |
|
| report results to tech support. |
|
|
|
System Timing | Selected Timing Source is | • Verify that system timing is correctly configured |
Source Unlocked | not present or clock is out | for the desired clock. |
(displayed on Ter- | of tolerance | • Verify that the interface cable to clock source is |
minal Interface, |
| present. |
“System Status”) |
| • Temporarily configure the system to operate off |
|
| of internal timing. Verify that the system can lock |
|
| to this clock. |
|
|
|
Cannot pass data | Misconfiguration, improper | • Verify that the T1 signal is being received. If not, |
from T1 interface | cabling | check that the cabling is correct. |
to V.35 port |
| • Verify that the T1 is being received without er- |
|
| rors. If not, |
|
| ing are set properly. |
|
| • Verify that desired dedicated map is active. |
|
| • Verify that bandwidth is mapped to the correct |
|
| V.35 port. |
|
| • Verify that the V.35 port is set to the correct data |
|
| rate (terminal interface). |
|
| • Check T1 performance using the terminal inter- |
|
| face; if excessive errors, report fault to the Telco. |
|
| • Verify proper state of DTE signals via the termi- |
|
| nal interface or the LCD front panel. |
|
|
|
| ATLAS 800 PLUS User Manual |