Appendix B

Troubleshooting

 

 

 

Table B-1.Troubleshooting

SYMPTOM

POSSIBLE CAUSES

TROUBLESHOOTING TIPS

 

 

 

Power-up Self-Test

Modules seated improp-

Remove all modules and cycle power to the unit.

Fails

erly, module failure

If self-test still fails, call Technical Support and

 

 

report the results. If the self-test now passes, re-

 

 

insert modules one at a time, running the self test

 

 

after installing each module. When an installed

 

 

module causes the self-test to fail, note it and

 

 

report results to tech support.

 

 

 

System Timing

Selected Timing Source is

• Verify that system timing is correctly configured

Source Unlocked

not present or clock is out

for the desired clock.

(displayed on Ter-

of tolerance

• Verify that the interface cable to clock source is

minal Interface,

 

present.

“System Status”)

 

• Temporarily configure the system to operate off

 

 

of internal timing. Verify that the system can lock

 

 

to this clock.

 

 

 

Cannot pass data

Misconfiguration, improper

• Verify that the T1 signal is being received. If not,

from T1 interface

cabling

check that the cabling is correct.

to V.35 port

 

• Verify that the T1 is being received without er-

 

 

rors. If not, double-check that framing and cod-

 

 

ing are set properly.

 

 

• Verify that desired dedicated map is active.

 

 

• Verify that bandwidth is mapped to the correct

 

 

V.35 port.

 

 

• Verify that the V.35 port is set to the correct data

 

 

rate (terminal interface).

 

 

• Check T1 performance using the terminal inter-

 

 

face; if excessive errors, report fault to the Telco.

 

 

• Verify proper state of DTE signals via the termi-

 

 

nal interface or the LCD front panel.

 

 

 