Chapter 5. Using the Terminal Menu
Chain Port Overrun Errs
Read security: 5
Displays the number of overrun errors. This field is
Chain Port Framing Errs
Read security: 5
Displays the number of received framing errors. This field is
SYSTEM CONFIGURATION
The System Config menu allows you to set up the ATLAS operational configura- tion. Figure
Figure 5-4. System Configuration Menu
Primary Timing Source Write security: 3; Read security: 5
Selects the primary timing source. You can select either INTERNAL or a port from one of the installed modules.
Backup Timing Source
Write security: 3; Read security: 5
Selects the secondary timing source. You can select either INTERNAL or a port from one of the installed modules. ATLAS 800PLUS uses the backup timing source if the primary timing source goes into alarm. The Backup Timing Source should be different from the Primary Timing Source.
ADLP Address
Write security: 2; Read security: 5
Shows the system ADTRAN Data Link Layer Protocol (ADLP) address for con- necting remote devices to management software (such as
Session Timeout
Write security: 3; Read security: 5
Defines the number of seconds the terminal session must remain idle before the session times out. You can enter zero to deactivate this option (the session will never time out).