Chapter 5. Using the Terminal Menu
5-12 ATLAS_ 800PLUS User Manual 61200226L1-1
Chain Port Overrun Errs
Read security: 5
Displays the number of overrun errors. This field is read-only.
Chain Port Framing Errs
Read security: 5
Displays the number of received framing errors. This field is read-only.
SYSTEM CONFIGURATION
The System Config menu allows you to set up the ATLAS operational configura-
tion. Figure 5-4 shows the items included in this menu.
Figure 5-4. System Configuration Menu
Primary Timing Source
Write security: 3; Read security: 5
Selects the primary timing source. You can select either INTERNAL or a port from
one of the installed modules.
Backup Timing Source
Write security: 3; Read security: 5
Selects the secondary timing source. You can select either INTERNAL or a port
from one of the installed modules. ATLAS_ 800PLUS uses the backup timing
source if the primary timing source goes into alarm. The Backup Timing Source
should be different from the Primary Timing Source.
ADLP Address
Write security: 2; Read security: 5
Shows the system ADTRAN Data Link Layer Protocol (ADLP) address for con-
necting remote devices to management software (such as T-Watch PRO). The
allowable range is between 2 and 65520. Enter a value not used by any of the TSU
units controlled by the management software.
Session Timeout
Write security: 3; Read security: 5
Defines the number of seconds the terminal session must remain idle before the
session times out. You can enter zero to deactivate this option (the session will
never time out).