Chapter 8. Updating Firmware

15.The Previous Update Status field indicates the results of the last firmware update for the particular slot chosen. If a firmware update has not been attempted for the particular slot, the Previous Update Status will display Has not been attempted.

16.After completing the configuration of all the above parameters, select the Begin Firmware Update field to activate the update process. This field requires user confirmation and will set up the module to initiate a TFTP upload with the specified network server. Once the update process begins, this field changes to Cancel Update to allow you to cancel the current update in progress.

17.During the TFTP upload process, various status messages will be provided in the Current Update Status field to indicate progress. These are described as follows:

TFTP -

Indicates communication with the TFTP

Contacting Server

network server is trying to be established

 

with the specified server address in the

 

TFTP Server IP Address field.

 

 

TFTP -

Indicates communication with the TFTP

Beginning TFTP Transfer

network server has been established and

 

the update file is being transferred

 

between ATLAS and the TFTP network

 

server.

 

 

TFTP - Completed

Indicates the ATLAS product successfully

 

received the update file.

 

 

TFTP -

Indicates the TFTP network server was

Error: File Not Found

unable to locate the specified file name or

 

path in the TFTP Server Filename field.

 

 

TFTP -

Indicates the TFTP network server denied

Error: Access Violation

ATLAS access to the given update file

 

name and path. Please verify

 

appropriate user rights are selected for

 

the specified path.

 

 

TFTP -

An unknown operation was detected by

Error: Illegal Operation

ATLAS when transferring the update file

 

from the TFTP network server.

 

 

TFTP -

Indicates the user selected Cancel Update

Error: User aborted

to abort reception of the update file from

 

the TFTP network server.

 

 

18.When the update process has completed successfully, the menu screen will display Idle in the Current Update Status field and Module Update Complete in the Previous Update Status field. In the event an error occurred during the update process, the Previous Update Status field will display the appropriate error message. Please go to step 7 and attempt the update process again. If the same error occurs, please contact ADTRAN Technical Support.

19.If the update of the module was successful, the module will either restart immediately and resume operation or restart at the specified time and day of the week, depending on your selection.

20.To update additional modules, go to Step 6 and select the appropriate slot.