Chapter 2. Installation
Table 2-2. Control Out/Chain Out Pinout
PIN NAME DESCRIPTION
1 | GND | Ground - connected to unit chassis. |
Connect to GND of next unit (pin1).
2UNUSED —
3 TX DATA Data transmitted to chained units by the ATLAS. Connect to RX DATA of the next unit (chain in pin 3).
4UNUSED —
5 | RX DATA | Data received from chained units by the ATLAS. |
|
| Connect to TX DATA of the next unit (chain in pin 5). |
6,7,8 | UNUSED | — |
|
|
|
Network Connection
The two
The two Network Interface (NI) ports comply with the applicable ANSI and
AT&T® standards.
The NIs provide the following functions:
•AMI or B8ZS coding
•Manual line build out
•D4 or ESF framing
•Network performance monitoring and reporting
•Test loopbacks with QRSS generation and checking
•Extensive self test
Connection
The network connection is as follows:
Connector type | (USOC) |
Part number | AMP# |
| ATLAS 800PLUS User Manual |