3. Upper cover unit
1) Remove the face-down tray.
2) Remove the 2 screws.
Screws
Figure 3-2-6
3) Open the delivery cover unit and then
remove the 2 screws.
Screws
Figure 3-2-7
4) Pulling the knob toward you, lift the
upper cover unit and disconnect the
connector from the inside.
Knob Upper cover unit
Figure 3-2-8
5) Unhook the 2 claws and then remove
the control panel unit.
Claws Control panel unit
Figure 3-2-9
3 - 4