FM-3 Programming Module Reference Manual

Figure 66: Index Velocity Profile

Index.0.CompoundInitiate ‘Incremental,Dist=5.000in,Vel=50in/s

Index.1.CompoundInitiate ‘Incremental,Dist=20.000in,Vel=75in/s

Index.2.Initiate‘Incremental,Dist=10.000in,Vel=30in/s

Wait For Index.AnyCommandComplete

Complex Velocity Profile

Drive Output 3 ONOFF

Drive Output 2 ONOFF

Drive Output 1 ONOFF

Velocity

Index 0

Index 1

Index 2

 

 

Time

Figure 67:

Index Velocity Profile with Drive Outputs

Index.0.CompoundInitiate

‘Incremetal,Dist=5.000in,Vel=50in/s

DriveOutput.1=ON

‘Turns ON immediately after Index.0 is started

Index.1.CompoundInitiate

‘Incremental,Dist=20.000in,Vel=75in/s

DriveOutput.2=ON

‘Turns ON immediately after Index.1 is started

Index.2.Initiate

‘Incremental,Dist=10.000in,Vel=30in/s

DriveOutput.3=ON

‘Turns ON immediately after Index.2 is started

Wait For Index.AnyCommandComplete

DriveOutput.1=OFF

‘Turns OFF after Index.2’s command is completed

DriveOutput.2=OFF

‘Turns OFF after Index.2’s command is completed

DriveOutput.3=OFF

‘Turns OFF after Index.2’s command is completed

Home.Initiate

This program instruction is used to initiate the home.

A comment is automatically inserted after the Home.Initiate instruction which shows key data about the particular home. The comment starts with the apostrophe ‘ character.

A “Wait For Home.AnyCommandComplete” instruction is not required because the home is actually a program which already has a “Wait For” instruction.

Example:

Home.0.Initiate‘Sensor,Offset=2.000in,Vel=-10.0in/s

128

Page 142
Image 142