FM-3 Programming Module Reference Manual

Accelerating

Home.#.Accelerating

Active during any acceleration while the specified home is in progress. Accelerating may turn off and on again based on the type of Home selected. Accelerating will activate during the Home back off sensor motion.

At Velocity

Home.#.AtVel

This source is activated when the home velocity is reached when a the specified home is in progress. It will activate and deactivate base on the home. Home At Velocity will not be activated during back off sensor portion of the home.

Calculated Offset

Home.#.CalculatedOffset

The Calculated offset is the distance travelled during the deceleration ramp from the home velocity to a stop. Calculated by PowerTools.

Command Complete

Home.#.CommandComplete

This source is active when the specified home command is completed, if a stop is activated before the home has completed the function or if the Home Limit Distance has been exceeded it will not be activated. Inactive when a home command is executed.

Command In Progress

Home.#.CommandInProgress

This source is activated when the Home is initiated and remains active until all motion related to the Home has completed.

Deceleration

Home.#.Decel

The Deceleration ramp parameter is used during all the home moves specified in user units.

156

Page 170
Image 170
Emerson FM-3 Home.#.Accelerating, Home.#.AtVel, Home.#.CalculatedOffset, Home.#.CommandComplete, Home.#.CommandInProgress