FM-3 Programming Module Reference Manual

Velocity View

The Velocity View allows the setup of feedrate override details.

By selecting Velocity in the Hierarchy View, the Velocity View will appear on the right (see Figure 33).

Figure 33:

Velocity View

Settings Group

FeedRate Override

This parameter is used to scale all motion. It can be described as scaling in real time. The default setting of 100% will allow all motion to occur in real time. A setting of 50% will scale time so that all moves run half as fast as they do at 100%. A setting of 200% will scale time so that all moves run twice as fast as they would at 100%. FeedRate Override is always active and affects all motion, including accels, decels, dwells, and synchronized motion. This parameter may be modified via Modbus or in a program.