Parameter Descriptions

Torque Limit

TorqueLimitEnable

This destination is used to enable the TorqueLimit. This is level sensitive.

Travel Limit Minus Activate

TravelLimitMinusActivate

This destination is used to activate the travel limit minus fault. It should be assigned to the travel limit minus sensor. When it is activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This is level sensitive.

Travel Limit Minus Active

TravelLimitMinusActive

This source is active when the TravelLimitMinusActivate is active. When this source is active motion is allowd in the positive direction only.

Travel Limit Plus Activate

TravelLimitPlusActivate

This destination is used to activate the travel limit plus fault. It should be assigned to the travel limit plus sensor. When it is activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This is level sensitive.

Travel Limit Plus Active

TravelLimitPlusActive

This source is active when the TravelLimitPlusActivate is active. When this source is active motion is allowd in the negative direction only.

Decimal Places

TorqueUnits.Decimal

This parameter is the decimal point location for user torque units.

Units Name

TorqueUnits.Name

The User can specify a torque unit name of up to 12 characters. Default is % Cont.