Quick Start

Enable Following Error – This checkbox enables (when checked) and disables the following error fault capability. If checked, a following error fault is generated whenever following error exceeds the value entered in the parameter box. If unchecked, a following error fault will never be generated.

Following Error Limit – If Following Error meets or exceeds this value, a Following Error Fault will be generated.

Enable Software Travel Limits - This checkbox enables (when checked) and disables the software travel limits. If enabled, the software travel limits are not active unless the Absolute Position Valid Source is active. (For more information please see Software Travel Limits information in the Setting Up Parameters section of the Reference Manual.)

Software Travel Limit + and - - If the position feedback ever exceeds these values when traveling in a positive or negative direction, the motor will come to a stop at the Travel Limit Decel rate defined on the Ramps view.

Velocity View

This view sets up the feedrate override velocity. If your application does not call for an overall scaling factor, leave this at the default of 100%.

Ramps View

You must setup the deceleration rate to be used on the Ramps view if a travel limit is encountered.